Standard injectors are divided into pintle-type and orifice-plate types. The pintle type comprises S-series and T-series units; S-series injectors are mainly used to test fuel pumps for small and medium power engines, and T-series for high power engines such as marine and locomotive pumps. A range of orifice-plate standard injectors is available for testing different pump types, including low-inertia and conventional designs, with orifice sizes of Φ0.4, Φ0.5, Φ0.6, 0.7 and Φ0.8.
S-series pintle standard injectors have been used in China for many years. As pump-end pressure and delivery volume have risen, they can no longer readily meet the testing needs of new pumps and are suitable only for older pump types such as A, B, I and II pumps.
Orifice-plate injector assemblies have long been used in developed countries; conventional types appeared in the 1960s and low-inertia types became widespread as pump technology advanced. With mass production of P-type pumps in China, low-inertia orifice-plate standard injectors were developed specifically for testing them and are widely used by pump and nozzle manufacturers and service stations. They offer high measurement accuracy, a wide flow range (flow characteristics can be matched by changing the orifice plate while faithfully reflecting pump behaviour) and long service life.
P-type fuel injection pumps are increasingly common in China. Testing them with low-inertia orifice-plate standard injectors resolves problems seen with conventional test injectors, such as difficulty balancing cylinders across rated speed, maximum torque speed and idle, and inaccurate fuel delivery settings. Selecting the correct standard injector is therefore essential; a low-inertia orifice-plate standard injector should be used for P-type pumps.
Requirements for selecting low-inertia orifice-plate standard injectors for newer pump types:
1. PW, PB, PN, P7100 and small-plunger PW2000 pumps use a Φ0.6 low-inertia orifice-plate standard injector with a Φ2 x Φ6 x 600 standard line.
2. P9 pumps and large-plunger PW2000 pumps use a Φ0.8 low-inertia standard injector; P9 pumps use a Φ3 x Φ8 x 1000 standard line and PW2000 pumps a Φ3 x Φ8 x 600 line.
3. BQ, PL and PM pumps use a Φ0.5 low-inertia orifice-plate standard injector with a Φ2 x Φ6 x 600 standard line.
4. For other pump types, select a suitable standard injector by reference to the above and the plunger diameter.
1. Before use, wash off the anti-rust oil and other contamination with petrol and keep the whole injector and high-pressure line assembly clean.
2. Check the opening pressure before use and set it according to the injector type purchased; monitor and adjust it frequently in the early period and periodically thereafter.
3. Test oil should comply with GB8029 calibration oil or GB252 No. 0 light diesel, settled for at least 48 hours and well filtered to ensure cleanliness, which strongly affects injector service life.
4. Maintain test oil temperature at 40±2 °C.
5. If flow changes noticeably after a period of use, check for: (1) a constricted or leaking line end; (2) a significant change in opening pressure; (3) iron filings or debris blocking the inlet union; (4) debris in the orifice plate; (5) wear of the nozzle couple seat by iron filings.
6. After a period of use the injector may be disassembled, cleaned and reassembled by personnel familiar with the assembly procedure, but do not interchange nozzle couples, orifice plates or high-pressure line assemblies, as this would affect delivery accuracy.
7. Calibrate standard injectors regularly, at intervals of six months.
Nationwide Service Hotline
Service Hotline